Best sellers
35 products
Sort by:
35 products
A modular track with two integrated USB ports
On your desk or in your furniture, group the power supply for your devices and the charging of your smartphones and tablets. The Genesis Track combines a 65.6 cm track with two integrated USB ports and a pre-installed 1.5 m cable. Choose a surface-mounted or semi-recessed installation and a brushed titanium or brushed black finish.
Why choose the GT 1.0 - Genesis?
Mount the track on the surface or integrate it semi-recessed according to your project. One model for two ways to arrange your space.
Two USB ports of 2.1 A each, or 4.2 A in total, allow you to charge your smartphones and tablets directly from the track.
The track accommodates up to five EUBIQ sockets. Design your installation according to the devices to be powered and position your sockets along the track.
The GT 1.0 is pre-wired with a 1.5 m cable in 3G2.5 mm², delivered without a male plug. Plan the connection suitable for your installation.
Two finishes for your interior
A brushed finish on an aluminum track, for a sober integration into your interior.
A dark finish to match your furniture and equipment.
Complete technical specifications
A compact format for your everyday devices
The GT 1.0 - Genesis is presented as a 65 cm model; its technical length is 65.6 cm. It combines up to five sockets and two integrated USB ports.
| Track length | Maximum capacity | Integrated charging |
|---|---|---|
| 65.6 cm | 5 sockets | 2 USB ports of 2.1 A |
How to install the GT 1.0 - Genesis?
Surface-mounted or semi-recessed, according to your interior design and the available support.
Consult the GT 1.0 documentation to prepare the support and perform the fixation corresponding to the chosen installation method.
The 1.5 m cable in 3G2.5 mm² is already installed on the track, but it does not include a male plug. The connection must be carried out by a qualified electrician.
Design your installation with GSS-compatible EUBIQ sockets, up to five sockets. The two USB charging ports are integrated into the track.
Modularity and USB charging
The Genesis Track allows you to position your sockets according to your needs, while its two USB ports remain integrated into the track.
Choose your sockets from the GSS-compatible EUBIQ range. The track can accommodate up to five sockets.
Charge your smartphones and tablets thanks to the two ports of 2.1 A each, without adding a separate USB module.
Additional information
A track to power your devices and charge your smartphones and tablets, with two USB ports already integrated.
Choose your finish and installation method: surface-mounted or semi-recessed.
The most elegant vertical power distribution for your professional spaces
Brushed titanium or brushed black aluminum finish, tool-free interchangeable Eubiq modular sockets and 4 USB ports. A freestanding column that powers up to 8 devices simultaneously, on both sides.
The essentials at a glance
4 advantages that make the difference
Total modularity
Each socket can be snapped in, moved and removed without tools. Adapt the column in real time with Schuko (Europe), UK (Great Britain) or international sockets. Ideal for hospitality and events.
Double-sided: up to 8 sockets
4 slots per side to power up to 8 devices simultaneously. Perfect for a central conference table or a counter serving two distinct areas.
4 USB ports
Two USB ports per side to charge smartphones and tablets without cluttering the sockets.
Integrated cable management
The side grooves channel and conceal excess cables. The installation remains neat, secure and professional, even with several connected devices.
Designed for public-facing spaces
In a professional space open to the public, power needs are varied and often unforeseen. The double-sided architecture of the TT 1.0 allows it to serve several users simultaneously on both sides of the column.
Hotels and lobbies
Welcome international guests with universal sockets adaptable to every nationality.
Meeting rooms and seminars
Central power supply for participants around a conference table.
Bars and lounge areas
Discreet device charging with a premium brushed titanium design.
Coworking and open spaces
Vertical distribution to eliminate power strips on the floor and trailing wires.
Showrooms and exhibitions
Elegant power supply for interactive presentations and touchscreens.
Complete technical specifications
Simplified commissioning
Position
Place the column in the desired location. Its stable aluminum base ensures a solid footing on any flat surface.
Connect
Plug the power cable (2.95 m) into a wall socket. The connection to the electrical network must be carried out by a qualified electrician.
Configure
Insert your choice of Eubiq socket modules — tool-free, in a few seconds. Adapt the configuration at any time.
What you need to know before ordering
Delivered without sockets
Eubiq socket modules are purchased separately, allowing you to build the exact configuration you need — in socket type, quantity and nationality. If your needs change, you do not replace the column: you simply adapt the modules.
Available in brushed aluminum or brushed black
The column is available in two finishes to blend into designer environments.
Simple installation
The column is delivered with a Schuko-compatible French plug: simply plug it into a standard socket to use it. Eubiq socket modules can be added, moved and configured without tools, allowing each user to easily adapt the column to their needs.
Frequently asked questions
Is the column compatible with British or international sockets?
Yes. The Eubiq system accepts a wide range of socket modules, including Schuko (Europe), UK (Great Britain) and international formats. You assemble your configuration according to the actual needs of your space.
What is the maximum supported power?
The column supports a voltage of 250 V with a maximum current of 20 A, or a maximum power of 5,000 W. Sufficient to power several professional devices simultaneously.
Can the USB ports charge tablets?
Yes, the built-in USB chargers are designed to power smartphones and touchscreens. For optimal charging of modern devices, check the amperage compatibility with the equipment used.
What is the difference between a column and a standard electrical column?
The column is a freestanding, placeable device, ideal for temporary or semi-permanent installation in the heart of a space. The standard column is generally fixed to the floor or ceiling. The TT 1.0 therefore offers greater placement flexibility.
Elegant, modular and designed for the demanding professional.
The TT 1.0 transforms electrical distribution into a real decorative asset.
The TT 1.0 electrical column is professional electrical power equipment. This product does not replace any electrical safety standard in force in your establishment.
Aluminum ring. Body finish in Titanium or black depending on the variant chosen. Integrated switch and blue LED for your Eubiq track installation.
Key features of this socket
The integrated switch allows you to control the power supply without unplugging the device.
The blue LED allows you to see if the socket is live.
Position your socket on your Eubiq track wherever it best suits your needs.
Ring and body finish
Aluminum ring. Body finish in Titanium or black depending on the variant chosen.
Technical specifications
| Socket type | Type G (BS1363) |
| Ring | Aluminum |
| Voltage | 220 - 250 Volts |
| Maximum current | 13 A |
| Maximum power | Approximately 3,250 W |
| Protection rating | IP20 (indoor use) |
| Diameter | 6.7 cm |
| Depth | 4.46 cm |
| Weight | 150 g |
| Use | Indoor use only |
| Compatible with all Eubiq power tracks? | Yes. The socket fits all Eubiq power tracks, whether surface-mounted, recessed into a desk, or attached under a table. Secured and removed with a simple quarter turn. |
| Suitable for use in bathrooms or outdoors? | No. With an IP20 rating, this socket is exclusively intended for dry indoor use, without exposure to moisture or water splashes. |
| Maximum supported power? | 13 A at 220-250 V, or approximately 3,250 W. Sufficient for the vast majority of standard office, audiovisual, and household appliances. |
| Indicator | Blue LED indicating power supply |
| Switch | Integrated |
| Mounting | Eubiq-compatible tracks |
Compatibility and socket type
Designed to accept Type G plugs, notably used in the United Kingdom. This track module does not replace a travel adapter.
Installation and use
Place the module on your Eubiq track according to the user guide.
Connect your device to the socket with a compatible plug, respecting the module's electrical specifications.
Then activate the socket by turning it a quarter turn. The blue LED indicates that it is live.
Frequently asked questions
What type of plug should I use?
Designed to accept Type G plugs, notably used in the United Kingdom. This track module does not replace a travel adapter.
What material is the ring made of?
Aluminum ring. Body finish in Titanium or black depending on the variant chosen.
Where should I install this socket?
On the compatible tracks in the Eubiq range. The integrated switch allows you to control the power supply and the blue LED indicates that it is live.
Use this module exclusively on compatible Eubiq power tracks and follow the product documentation. For any questions regarding electrical installation, consult a qualified electrician.
Aluminum ring. Body with a Titanium or black finish depending on the variant chosen. Integrated switch and blue LED for your Eubiq power track installation.
Key features of this socket
The integrated switch allows you to control the power supply without unplugging the device.
The blue LED allows you to see if the socket is live.
Position your socket on your Eubiq power track in the location that best suits your needs.
Ring and body finish
Aluminum ring. Body with a Titanium or black finish depending on the variant chosen.
Technical specifications
| Socket type | International |
| Ring | Aluminum |
| Voltage | 220 – 250 Volts |
| Maximum current | 16 A |
| Diameter | 6.7 cm |
| Depth | 4.46 cm |
| Weight | 145 g |
| Packaging dimensions | 8 x 8 x 7 cm |
| Protection rating | IP20 (indoor use) |
| Integrated USB port | No |
| Indicator | Blue power-on LED |
| Switch | Integrated |
| Mounting | Eubiq-compatible tracks |
Compatibility and socket type
Check the plug type of your device before use. International sockets are not compatible with plugs from Switzerland, Rwanda, Liechtenstein, Italy, Chile, Brazil, Israel, the West Bank, and the Gaza Strip. For E and F plugs, check for a suitable ground connection.
Installation and use
Place the module on your Eubiq power track according to the user guide.
Connect your device to the socket with a compatible plug, respecting the electrical specifications of the module.
Then activate the socket by turning it a quarter turn. The blue LED indicates that it is powered on.
Frequently asked questions
What type of plug should I use?
Check the plug type of your device before use. International sockets are not compatible with plugs from Switzerland, Rwanda, Liechtenstein, Italy, Chile, Brazil, Israel, the West Bank, and the Gaza Strip. For E and F plugs, check for a suitable ground connection.
What material is the ring made of?
Aluminum ring. Body with a Titanium or black finish depending on the variant chosen.
What should I install this socket on?
On the compatible tracks in the Eubiq range. The integrated switch allows you to control the power supply, and the blue LED indicates that it is powered on.
Use this module exclusively on Eubiq-compatible tracks and follow the product documentation. For any questions regarding electrical installation, consult a qualified electrician.
A plug to be connected to an electrical cable for your indoor equipment and installations. The PLT16 operates at 220 V, with a current of 16 A. Its red indicator light shows when it is powered.
Cable Connection
The PLT16 is connected directly to an electrical cable, according to the manufacturer's instructions. Its red indicator light shows when it is powered.
What is the PLT16 used for?
The PLT16 is a cableable plug designed to be connected to an electrical cable. Its selection depends on the equipment to be connected, the cable used, and the installation requirements. It should not be confused with a flush-mounted wall socket or a simple cable socket.
Technical Specifications
| Model | PLT16 |
| Type | Cableable plug |
| Brand | EUBIQ |
| Reference | 2037-0000-0100 |
| Voltage | 220 V |
| Current | 16 A |
| Indication | Red power indicator light |
| Indicated dimensions (L × W × H) | 9 × 10 × 7 cm |
| CE marking | CE, according to the product sheet information |
| Usage | Indoor, professional and residential |
Applications and Compatibility
The PLT16 can be considered for connecting office or workshop equipment, a technical cabinet or electrical rack, replacing an existing plug, or for a renovation project. Check the equipment specifications, wiring requirements, and available space before choosing it. Its compatibility with another accessory cannot be inferred from the brand or color.
Frequently Asked Questions
What are the electrical specifications?
The PLT16 is designed for a voltage of 220 V and a current of 16 A.
What is the red indicator light used for?
The red indicator light shows when the plug is powered.
Is the PLT16 a flush-mounted wall socket?
No. It is a cableable plug designed to be connected to an electrical cable.
Who should perform the connection?
A qualified electrician, following the manufacturer's instructions and working with the power turned off.
Can the PLT16 be used outdoors?
The product sheet specifies indoor use. For outdoor or damp environments, choose a product explicitly designed for those conditions.
What are the indicated dimensions?
The indicated dimensions are 9 × 10 × 7 cm.
Is it compatible with all installations?
No. Check the specifications of the equipment, cable, and plug in the documentation before proceeding with the connection.
Observe the electrical specifications and the manufacturer's instructions. Check that the product is suitable for the intended installation. The indicator light does not replace a check for the absence of voltage before working. If in doubt, consult a qualified electrician.
Choose your lengths and the areas to electrify
The SH1 trackway uses the same profile as the SH1 tracks sold in 60, 80, 100, and 120 cm lengths. The difference: you design your own installation. Create a custom length, a corner return, or even a room perimeter trackway, electrifying only the useful areas with SFC3 segments and completing the other sections with SFC2D cut to the required length.
Standard SH1 track or customizable SH1 trackway?
The same profile, two ways to prepare your project.
SH1 tracks in standard lengths
SH1 tracks are available in 60, 80, 100, and 120 cm lengths. Choose this solution when one of these lengths matches your layout.
Customizable SH1 trackway
Supplied bare in a 150 cm length that can be cut to size, the trackway allows you to customize the path, the final length, and the distribution of electrified areas. The components required for your configuration must be selected separately.
Design the installation you need
Electrify only certain areas
Position the SFC3 electrical segments where you want to use your EUBIQ sockets. It is not necessary to electrify the entire length of the installation.
Adjust the length with SFC2D
Complete the SFC3 segments with SFC2D blanking sections. The SFC2D can be cut to fill the non-electrified sections and achieve the desired final length.
Create returns and corners
Design a path suited to the room by selecting the necessary corners and connectors, rather than being limited to a standard straight length.
Create a room perimeter trackway
Run the trackway around the room and provide electrified areas only at useful locations: near a desk, cabinet, or workstation.
How to combine SFC3, SFC2D, and DS4?
| Component | Role in your installation |
|---|---|
| SH1 trackway | The aluminum profile that forms the path of your installation. |
| SFC3 electrical segment | Creates the electrified areas intended to receive EUBIQ sockets. |
| SFC2D blanking section | Completes the non-electrified sections. It can be cut to adjust the overall length. |
| DS4 for RJ45 | Allows RJ45 sockets to be installed at a fixed location between two SFC3 segments or at the end of the installation, instead of a section of SFC2D. Once installed, these RJ45 sockets cannot be moved along the track. |
| Corners and connectors | Allow you to create changes in direction and junctions in the path. |
| End caps | Close the ends of the trackway for a neat finish. |
Example layout: along a long wall, provide an SFC3 area at the desk, another near a cabinet, then complete the intermediate sections with SFC2D. The path remains continuous, but only the chosen areas are electrified.
SH1 profile specifications
Cable management and accessories
High-voltage and low-voltage wiring
The separation bracket creates two distinct compartments. The upper compartment can accommodate low-voltage cables, such as Ethernet.
Fixed RJ45 connections via DS4
RJ45 sockets are installed via DS4, between two SFC3 segments or at the end of the installation, instead of a section of SFC2D. They remain fixed and cannot be moved along the track. Plan their location when designing your installation.
Kitchen accessories
A groove under the profile allows bars or hooks to be clipped on to hang your utensils.
To be assembled separately: SFC3 segments, SFC2D blanking sections, DS4 for RJ45 sockets, corners, connectors, end caps, separation bracket, sockets, and other accessories according to your project. The bare trackway is not a pre-power track.
Prepare your custom installation
Map out the path
Measure the lengths and changes in direction: straight section, corner return, or room perimeter trackway.
Identify the areas to electrify
Choose the locations of the SFC3 segments based on the devices you want to power. For RJ45 sockets, plan DS4 at fixed locations between two SFC3 segments or at the end of the installation, instead of a section of SFC2D.
Complete with SFC2D
Provide blanking sections for the non-electrified sections and cut them to achieve the desired final length.
Prepare the cuts and mounting
The aluminum trackway can be cut with a hacksaw. For a more professional cut, use a circular saw equipped with a blade suitable for aluminum. Secure the profile, follow the tool's safety instructions, and deburr the edges after cutting. Choose fasteners suitable for the mounting surface.
Assemble and connect
Follow the documentation for the various components for assembly and connection. The electrical installation must be carried out by a qualified electrician.
Frequently asked questions
Is the SH1 trackway different from the profile of the standard SH1 tracks?
No, it uses the same profile as the SH1 tracks sold in 60, 80, 100, and 120 cm lengths. The difference lies in the configuration: the bare trackway allows you to design the path and electrified areas according to your project.
Should the entire length be electrified?
No. Use the SFC3 segments at the locations where you need sockets and complete the other sections with SFC2D blanking sections.
How are RJ45 sockets installed?
RJ45 sockets are installed via DS4, between two SFC3 segments or at the end of the installation, instead of a section of SFC2D. They remain fixed and cannot be moved along the track.
How do you achieve a precise length?
Adapt the length of the trackway to your project, then complete the SFC3 segments with cut SFC2D to achieve the desired length. Do not confuse adjusting the blanking section with cutting the electrical segment.
Can you run it around a room?
Yes. The customizable solution allows you to create a room perimeter trackway with the necessary corners and connectors, electrifying only certain areas.
Is the black finish available for this product?
No. The trackway presented here is brushed aluminum.
Additional information
The SH1 profile, to your measure.
Design the path, choose your SFC3 areas, and adjust the SFC2D sections to your installation.
A neat transition at every inside corner
Designed for EUBIQ's SH1 trunking, this fixed 90° inside corner angle allows you to create a junction in an inside corner. Made of plastic, it is available in an aluminum or matte black finish to match your installation.
Why choose a dedicated angle?
Designed for SH1 Trunking
A dedicated piece for the SH1 profile to create the transition between two trunking sections in an inside corner.
Cable Routing
Follows the cable routing around the change of direction. Check their positioning and the absence of unburred cut edges during installation.
Snap-Fit Installation
Snaps onto SH1 trunking sections to create a 90° junction in an inside corner.
Two Finishes
Choose the aluminum or matte black finish depending on the desired variant. The finish describes the appearance of the part, not its plastic material.
DIY Cut vs. Dedicated Angle
- Requires preparing and adjusting the cuts
- Edges must be carefully deburred
- Joint precision depends on the quality of the cut
- Requires finishing work at the change of direction
- Dedicated piece for the SH1 profile
- Fixed 90° inside corner angle
- Snap-fit installation
- Aluminum or matte black finishes
Technical Specifications
This angle is designed exclusively for SH1 trunking. Check your trunking reference, the finish, and the corner geometry before ordering.
In what contexts should it be used?
Workstations and Desks
Extend your SH1 route in an inside corner to follow the cable routing of the installation.
Workshops and Technical Areas
Create a dedicated junction at the inside corners of your trunking route.
Residential Fit-outs
Create a neat transition in the inside corners of a room by choosing a finish that matches your trunking.
Commercial Premises
Maintain a consistent appearance in offices, reception areas, or commercial premises.
5-Step Installation Guide
Position the first SH1 section
Prepare the length of trunking and position it along the wall up to the inside corner, according to the mounting instructions.
Snap in the inside corner angle
Present the angle at the end of the first section and snap it in without forcing it.
Connect the second section
Insert the second section into the other opening, perpendicular to the first, to follow the inside corner.
Check alignment and fastening
Check the fit of the elements and secure the trunking according to the SH1 range recommendations and the characteristics of the support.
Check cable routing and closure
Check the cable routing before completing the assembly according to the system documentation. Any work on the electrical installation must be carried out without power by a qualified electrician.
Material and Finishes
Plastic Material
The part is made of plastic. The aluminum finish does not mean it is made of metal.
Aluminum Finish
An aluminum appearance to visually complete your SH1 installation.
Matte Black Finish
A second finish offered on this product sheet, to be selected according to the desired appearance.
Frequently Asked Questions
What is the difference between an inside and outside corner angle?
The inside corner angle corresponds to an inside corner, where the walls form a recess. The outside corner angle goes around a protruding corner. The two parts are not interchangeable.
Is it compatible with other trunking?
It is designed specifically for EUBIQ's SH1 trunking. Do not assume compatibility with another profile, even one with similar dimensions.
Is it made of aluminum?
No. Its material is plastic. The available finishes are aluminum and matte black.
Is the angle adjustable?
No. It is fixed at 90° and is suitable for inside corners matching this geometry.
How do I choose the finish?
Select the Alu or Black variant depending on your trunking and the other accessories, to maintain visual consistency.
Additional Information
A neat transition in the inside corners of your SH1 installation.
Fixed 90° inside corner angle · Aluminum or matte black finishesThe pair — a neat finish at both ends of the track
Close the open ends of your EUBIQ SH1 trunking with this pair of dedicated end caps. They screw onto the profile to conceal its opening and provide a neat finish to the installation. Screws and screw caps are included with the pair. Choose the Aluminium or Black finish depending on the desired variant.
Why choose dedicated end caps?
Closes the ends
They close the open ends of the SH1 trunking and conceal the inside of the profile at the start and end of the track.
Designed for the SH1 profile
Components designed for this trunking model, distinct from accessories intended for other profiles.
Screw-on mounting
The end caps screw onto the ends of the SH1 trunking. Screws and screw caps are included with each pair.
Two finishes
The Aluminium and Black variants allow you to choose a finish that matches your trunking and other accessories.
End cap or other finishing element?
- The SFC2D closes non-electrified longitudinal sections
- Connectors are intended for track junctions
- Angles allow for changes in direction
- These elements do not replace end caps
- Close the open ends of the profile
- Finish the start and end of the track
- Screw onto the SH1 trunking
- Sold as a pair, with screws and screw caps included
Technical specifications
Check your trunking reference and the finish before ordering. Closing the ends does not indicate that the entire assembly is watertight.
To finish your SH1 installation
Residential settings
Neatly finish the visible ends of an SH1 track in your home.
Offices and workstations
Finish the lengths of trunking used in your custom installation.
Commercial premises
Maintain a consistent appearance with other SH1 accessories in workspaces and commercial premises.
3-step installation guide
Prepare the SH1 trunking
Check that the profile is securely fixed and that the components and cables are correctly positioned, according to the installation documentation.
Screw on the end caps
Position one cap at each end to be closed and secure it with the screws provided. Follow the SH1 system assembly instructions.
Fit the screw caps and check the finish
Fit the screw caps provided, then check that the end caps are properly fitted and secure. All work on the electrical installation must be carried out without power by a qualified electrician.
One pair for two ends
The package contains two end caps, screws and screw caps. Identify the open ends to be closed on your SH1 track to determine the quantity required. A track with several independent lengths may require several pairs.
Frequently asked questions
What are these end caps used for?
They close the open ends of the SH1 trunking and conceal the inside of the profile for a neat finish.
Are they sold individually?
No. They are sold as a pair, meaning two end caps, with screws and screw caps included. Count the open ends of your track to determine the quantity required.
Are they compatible with other trunking?
They are designed exclusively for the EUBIQ SH1 trunking. For another model, choose the end caps designed for the relevant profile.
How do they differ from the SFC2D?
The SFC2D closes a non-electrified longitudinal section. The end cap closes the end of the profile. The two elements have different functions.
How are they fixed?
They screw onto the ends of the SH1 trunking. Screws and screw caps are included with each pair. They are not simply snapped into place.
What finishes are available?
The available variants are Aluminium and Black. Select the one that matches your trunking and other accessories.
Additional information
A neat SH1 installation right to the ends.
The pair · Screw-on mounting · Screws and screw caps included · Aluminium or Black finishesShowing 24/35
NextCollections featured
- Choosing a selection results in a full page refresh.
- Opens in a new window.